Freescale Semiconductor /MK60DZ10 /MC /PMCTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as PMCTRL

7 43 0 0 00 0 0 0 0 0 0 0 0 (000)LPLLSM 0 (00)RUNM 0 (0)LPWUI

RUNM=00, LPLLSM=000, LPWUI=0

Description

Power Mode Control Register

Fields

LPLLSM

Low Power, Low Leakage Stop Mode

0 (000): Normal stop

2 (010): Very low power stop (VLPS)

3 (011): Low leakage stop (LLS)

5 (101): Very low leakage stop 3 (VLLS3)

6 (110): Very low leakage stop 2 (VLLS2)

7 (111): Very low leakage stop 1 (VLLS1)

RUNM

Run Mode Enable

0 (00): Normal run mode

2 (10): Very low power run mode

LPWUI

Low Power Wake Up on Interrupt

0 (0): The voltage regulator remains in stop regulation on an interrupt

1 (1): The voltage regulator exits stop regulation on an interrupt